BDC-D
Product description
BDC-D — floor-standing DC station with two outputs
BDC-D is a floor-standing DC fast charging station with a total of 30kW to 240 kW available power and two configurable outputs. Power is dynamically distributed between the two vehicles within the overall station limit and vehicle, voltage and current limits.
Main advantages
- Total rated power: 30kW to 240 kW
- Two outputs; connector configuration according to project, including CCS2 + CCS2
- Cables length 5 m
- LCD 21 inch touch screen and LED indicator
- Authorisation: RFID card and app
- Communication: OCPP 1.6J, Ethernet, 4G and Wi‑Fi
- Case protection: IP55, IK10; screen IK08
- Floor mounting, galvanized sheet, forced air cooling
Models and prices
| Model | Power | Price including VAT |
|---|---|---|
| BDC-D60 | 60 kW | 2.225.896,69 RSD |
| BDC-D80 | 80 kW | 2.419.452,92 RSD |
| BDC-D90 | 90 kW | 2.568.342,33 RSD |
| BDC-D120 | 120 kW | 2.903.343,51 RSD |
| BDC-D150 | 150 kW | 3.275.567,03 RSD |
| BDC-D160 | 160 kW | 3.350.011,74 RSD |
| BDC-D180 | 180 kW | 3.591.957,03 RSD |
| BDC-D210 | 210 kW | 3.908.347,03 RSD |
| BDC-D240 | 240 kW | 4.280.570,55 RSD |
Prices include VAT 20%. Converted as of 04.10.2026. at the NBS middle exchange rate of 117,4948 RSD/EUR. Final connector configuration, equipment, delivery and installation terms are confirmed in the quotation.
Technical characteristics
| Dimensions | 800 × 800 × 1800 mm |
|---|---|
| Weight | up to 400 kg |
| AC input | 380–415 V AC, 3P+N+PE; rated input current 304 A; 50/60 Hz |
| Output voltage range | CCS1/CCS2/GBT/NACS: 150–1000 V DC; CHAdeMO: 150–500 V DC |
| Output current | CCS1/CCS2/GBT/NACS: 0–250 A; CHAdeMO: 0–150 A |
| Efficiency | at least 95% |
| Power factor | at least 0,99 at 100% load |
| Operating temperature | -30 °C to +50 °C |
| Storage temperature | -30 °C to +85 °C |
| Operating humidity | 5–95% |
| Working altitude | below 2000 m |
Safety features: emergency stop, overvoltage and undervoltage protection, overload and leakage current protection, earthing protection, overheating and atmospheric surge protection.
The technical values are taken from the DARSA catalog. The final configuration of the connections and delivery conditions are confirmed for the specific project.
Documentation and configuration
Description, variants and technical values are cross-referenced from DARSA Catalog AC/DC 2026, DARSA portfolio and technical documentation. The datasheet is available in the download section. The final specification is confirmed for the selected model.
Request a quote for your location