Growatt SPF TL HVM
Product description
Off-grid-tied inverters with a choice of power, battery voltage and support for parallel operation.
Models and technical data
| Model | Rated power (kW) | Battery (V) | Max. open-circuit PV voltage (V) |
|---|---|---|---|
| SPF 2000TL HVM-24 | 2 | 24 | 102 |
| SPF 3000TL HVM-24 | 3 | 24 | 102 |
| SPF 2000TL HVM-48 | 2 | 48 | 145 |
| SPF 3000TL HVM-48 | 3 | 48 | 145 |
| SPF 5000TL HVM | 5 | 48 | 145 |
| SPF 5000TL HVM-P | 5 | 48 | 145 |
| SPF 4000TL HVM | 4 | 48 | 145 |
| SPF 4000TL HVM-P | 4 | 48 | 145 |
IP20, for protected indoor spaces. Only the HVM-P version supports parallel operation, up to six devices.
This family is not the same as SPF HVM-WPV with high voltage PV input.
Manufacturer's documentation
SPF 4000TL HVM / HVM-P — performance characteristics
Single-phase off-grid-tied inverters 4 kVA / 4 kW, output 230 V ±5%, 50/60 Hz, battery 48 V. Maximum open-circuit PV voltage 145 V, MPPT range 60–115 V and peak efficiency 93%. HVM-P is a version with support for parallel operation. These are not models HVM-24G2 with battery from 24 V and PV input up to 500 V.
The versions are confirmed in the original Growatt SPF 2000–5000TL HVM manual (202109), the Validity section and tables 2–3, as well as the attached CE-LVD certificate. The current 202509 datasheet does not list 4 kW; the attached original manual applies to the added models.